FILE,LAD 2 SOR,0 BST,1 XIC,B3:0/3 XIO,I:1/2 NXB,1 BST,2 XIC,B3:0/1 XIC,I:1/1 NXB,2 BST,3 XIC,B3:0/0 NXB,3 XIO,B3:0/0 XIO,B3:0/1 XIO,B3:0/2 XIO,B3:0/3 BND,3 BND,2 BND,1 BST,1 XIO,B3:0/1 NXB,1 XIO,I:1/0 BND,1 OTE,B3:0/0 EOR,0 RCM,THE NEXT FOR RUNGS ARE REPRESENT THE STATE MACHINE FOR THE OVEN COVERED IN CLASS. SOR,1 BST,1 XIC,B3:0/0 XIC,I:1/0 NXB,1 XIC,B3:0/1 BND,1 BST,1 XIO,B3:0/2 NXB,1 XIO,I:1/2 BND,1 BST,1 XIO,B3:0/0 NXB,1 XIO,I:1/1 BND,1 OTE,B3:0/1 EOR,1 RCM,USE THE I/O SIMULATOR to test this program in Logixpro. SOR,2 BST,1 XIC,B3:0/1 XIC,I:1/2 NXB,1 XIC,B3:0/2 BND,1 BST,1 XIO,B3:0/3 NXB,1 XIO,I:1/3 BND,1 BST,1 XIO,B3:0/3 NXB,1 XIO,I:1/1 BND,1 OTE,B3:0/2 EOR,2 RCM, SOR,3 BST,1 XIC,B3:0/2 XIC,I:1/3 NXB,1 XIC,B3:0/3 BND,1 BST,1 XIO,B3:0/0 NXB,1 XIC,I:1/2 BND,1 OTE,B3:0/3 EOR,3 RCM, SOR,4 BST,1 XIC,B3:0/1 NXB,1 XIC,B3:0/2 BND,1 OTE,O:2/0 EOR,4 RCM,THIS IS THE SECTION OF LADDER LOGIC THAT MAPS STATES TO OUTPUTS OF THE PLC. SOR,5 BST,1 XIC,B3:0/2 NXB,1 XIC,B3:0/3 BND,1 OTE,O:2/1 EOR,5 RCM, SOR,6 EOR,6 RCM, SOR,7 END,7 RCM, FILE,SBR 3: SOR,0 END,0 RCM, FILE,SBR 4: SOR,0 END,0 RCM, FILE,SBR 5: SOR,0 END,0 RCM, FILE,SBR 6: SOR,0 END,0 RCM, FILE,SBR 7: SOR,0 END,0 RCM, FILE,SBR 8: SOR,0 END,0 RCM, FILE,SBR 9: SOR,0 END,0 RCM, BTBL 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 NTBL 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 FTBL 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 SYMBOLS B3:0/3 COOL STATE B3:0/0 OFF STATE B3:0/1 PREHEAT STATE B3:0/2 SUPERHEAT ST I:1/1 STOP I:1/0 START I:1/2 TEMP 1 I:1/3 TEMP 2 O:2 HEAT ON O:2/1 LOCK DOOR